• 1920x300 nybjtp

Xitoy ishlab chiqaruvchisi CJM3-250 225A 35kA/25kA MCCB kalıplanmış korpusli elektron to'xtatuvchisi

Qisqacha tavsif:

Ilova

CJMM1 seriyali qoliplangan korpusli elektron to'xtatuvchi (bundan keyin elektron to'xtatuvchi deb yuritiladi) 800V nominal izolyatsiya kuchlanishiga, 690V nominal ish kuchlanishiga va 10A dan 630A gacha nominal ish oqimiga ega AC 50/60HZ quvvat taqsimlash tarmog'i sxemasi uchun mos keladi, u quvvatni taqsimlash va ortiqcha yuklanish, qisqa tutashuv, past kuchlanish va boshqa nosozliklar tufayli elektron va elektr ta'minoti uskunalarining shikastlanishining oldini olish uchun ishlatiladi, shuningdek, motorni kamdan-kam ishga tushirish, shuningdek, ortiqcha yuklanish, qisqa tutashuv va past kuchlanishdan himoya qilish uchun ham ishlatiladi. Ushbu elektron to'xtatuvchi kichik hajm, yuqori uzilish qobiliyati, qisqa yoy (yoki noarsing) va boshqalar kabi afzalliklarga ega, u signalizatsiya kontakti, shuntni bo'shatish, yordamchi kontakt va boshqalar kabi aksessuarlar bilan jihozlanishi mumkin, bu foydalanuvchi uchun ideal mahsulotdir. Qoldiq tok elektron to'xtatuvchisi vertikal ravishda o'rnatilishi (vertikal o'rnatish) yoki gorizontal ravishda o'rnatilishi (gorizontal o'rnatish) mumkin. Mahsulot IEC60947-2 va Gb140482 standartlariga mos keladi.


Mahsulot tafsiloti

Mahsulot teglari

Mahsulot modeli

CJ: Korxona kodi
M: Qoliplangan korpusli elektron to'xtatuvchi
1: Dizayn raqami
□: Kadrning nominal oqimi
□: Sindirish qobiliyati xarakteristikasi kodi/S standart turni bildiradi (S tushirib qolishi mumkin) H yuqori turni bildiradi

Eslatma: To'rt fazali mahsulot uchun to'rt xil neytral qutb (N qutb) mavjud. A turdagi neytral qutb ortiqcha tokni o'chirish elementi bilan jihozlanmagan, u har doim yoqilgan va boshqa uchta qutb bilan birga yoqilmagan yoki o'chirilmagan.
B turidagi neytral qutb ortiqcha tokni o'chirish elementi bilan jihozlanmagan va u boshqa uchta qutb bilan birga yoqilgan yoki o'chirilgan (neytral qutb o'chirilishidan oldin yoqilgan). C turidagi neytral qutb ortiqcha tokni o'chirish elementi bilan jihozlangan va u boshqa uchta qutb bilan birga yoqilgan yoki o'chirilgan (neytral qutb o'chirilishidan oldin yoqilgan). D turidagi neytral qutb ortiqcha tokni o'chirish elementi bilan jihozlangan, u har doim yoqilgan va boshqa uchta qutb bilan birga yoqilgan yoki o'chirilgan emas.

1-jadval

Aksessuar nomi Elektron nashr Murakkab ajralib chiqish
Yordamchi kontakt, kuchlanish ostida uzilish, alam kontakt 287 378
Ikkita yordamchi aloqa to'plami, signal aloqasi 268 368
Shuntni bo'shatish, signalizatsiya kontakti, yordamchi kontakt 238 348
Kuchlanish ostida, signal bilan aloqa 248 338
Yordamchi kontaktli signalizatsiya kontakti 228 328
Shuntni bo'shatish signalizatsiya kontakti 218 318
Yordamchi kontaktning past kuchlanishli chiqarilishi 270 370
Ikki yordamchi kontakt to'plami 260 360
Shuntning past kuchlanishli chiqarilishi 250 350
Shuntni bo'shatish uchun yordamchi kontakt 240 340
Past kuchlanishli uzilish 230 330
Yordamchi aloqa 220 320
Shuntning chiqarilishi 210 310
Signal aloqasi 208 308
Aksessuar yo'q 200 300

Tasniflash

  • Sindirish qobiliyati bo'yicha: standart turdagi (S turi) b yuqori sindirish qobiliyati turi (H turi)
  • Ulanish rejimi bo'yicha: a old plata ulanishi, b orqa plata ulanishi, c plagin turi
  • Ishlash rejimi bo'yicha: a) to'g'ridan-to'g'ri tutqich bilan ishlash, b) aylanish tutqichi bilan ishlash, c) elektr bilan ishlash
  • Qutblar soni bo'yicha: 1P, 2P, 3P, 4P
  • Aksessuar bo'yicha: signalizatsiya kontakti, yordamchi kontakt, shuntni bo'shatish, kuchlanish ostida bo'shatish

Oddiy xizmat ko'rsatish holati

  • O'rnatish maydonchasining balandligi 2000 m dan oshmasligi kerak
  • Atrof-muhit havosi harorati
  • Atrof-muhit havosining harorati +40℃ dan oshmasligi kerak
  • O'rtacha qiymat 24 soat ichida +35 ℃ dan oshmasligi kerak
  • Atrof-muhit havosining harorati -5 ℃ dan past bo'lmasligi kerak
  • Atmosfera holati:
  • 1 Bu yerdagi atmosferaning nisbiy namligi +40℃ eng yuqori haroratda 50% dan oshmasligi kerak va eng past haroratda yuqori bo'lishi mumkin, eng nam oydagi o'rtacha eng past harorat 25℃ dan oshmasa, 90% ga yetishi mumkin, harorat o'zgarishi tufayli mahsulot yuzasida kondensatsiya paydo bo'lishi mumkin.
  • Ifloslanish darajasi 3-sinf

Asosiy texnik parametr

1 O'chirgichlarning nominal qiymati
Model Imax (A) Texnik xususiyatlar (A) Nominal ish kuchlanishi (V) Nominal izolyatsiya kuchlanishi (V) Reanimatsiya (kA) ICS (kA) Qutblar soni (P) Yoy masofasi (mm)
CJMM1-63S 63 6,10,16,20
25, 32, 40,
50,63
400 500 10* 5* 3 ≤50
CJMM1-63H 63 400 500 15* 10* 3,4
CJMM1-100S 100 16,20,25,32
40,50,63,
80,100
690 800 35/10 22/5 3 ≤50
CJMM1-100H 100 400 800 50 35 2,3,4
CJMM1-225S 225 100,125,
160,180,
200,225
690 800 35/10 25/5 3 ≤50
CJMM1-225H 225 400 800 50 35 2,3,4
CJMM1-400S 400 225,250,
315,350,
400
690 800 50/15 35/8 3,4 ≤100
CJMM1-400H 400 400 800 65 35 3
CJMM1-630S 630 400,500,
630
690 800 50/15 35/8 3,4 ≤100
CJMM1-630H 630 400 800 65 45 3
Eslatma: 400V, 6A uchun sinov parametrlari isitishsiz chiqarilganda
2 Quvvat taqsimoti uchun ortiqcha oqimning har bir qutbi bir vaqtning o'zida yoqilganda teskari vaqtni uzish operatsiyasining xarakteristikasi
Sinov elementi Oqim (I/Kirish) Sinov vaqt zonasi Boshlang'ich holat
Qo'zg'almas tok 1.05 dyuym 2 soat(n>63A), 1 soat(n<63A) Sovuq holat
O'chirish oqimi 1.3In 2 soat(n>63A), 1 soat(n<63A) Darhol davom eting
1-sonli sinovdan keyin
3 Har bir qutb haddan tashqari ko'p bo'lganda teskari vaqtni uzish operatsiyasining xarakteristikasi
motorni himoya qilish uchun oqimning chiqarilishi bir vaqtning o'zida yoqilgan.
Joriy an'anaviy vaqtni sozlash Boshlang'ich holat Eslatma
1.0 dyuym >2 soat Sovuq holat
1.2 dyuym ≤2 soat 1-sonli sinovdan so'ng darhol davom etdi
1.5 dyuym ≤4 daqiqa Sovuq holat 10≤In≤225
≤8 daqiqa Sovuq holat 225≤In≤630
7.2 dyuym 4s≤T≤10s Sovuq holat 10≤In≤225
6s≤T≤20s Sovuq holat 225≤In≤630
4 Quvvatni taqsimlash uchun avtomatik o'chirgichning bir zumda ishlash xususiyati 10 dyuym + 20% ga, motorni himoya qilish uchun avtomatik o'chirgichning xususiyati esa 12ln ± 20% ga o'rnatiladi.

O'rnatish hajmi

CJMM1-63, 100, 225, Kontur va o'rnatish o'lchamlari (old panel ulanishi)

Olchamlari (mm) Model kodi
CJMM1-63S CJMM1-63H CJMM1-63S CJMM1-100S CJMM1-100H CJMM1-225S CJMM1-225
Kontur o'lchamlari C 85.0 85.0 88.0 88.0 102.0 102.0
E 50.0 50.0 51.0 51.0 60.0 52.0
F 23.0 23.0 23.0 22.5 25.0 23.5
G 14.0 14.0 17.5 17.5 17.0 17.0
G1 6.5 6.5 6.5 6.5 11.5 11.5
H 73.0 81.0 68.0 86.0 88.0 103.0
H1 90.0 98.5 86.0 104.0 110.0 127.0
H2 18.5 27.0 24.0 24.0 24.0 24.0
H3 4.0 4.5 4.0 4.0 4.0 4.0
H4 7.0 7.0 7.0 7.0 5.0 5.0
L 135.0 135.0 150.0 150.0 165.0 165.0
L1 170.0 173.0 225.0 225.0 360.0 360.0
L2 117.0 117.0 136.0 136.0 144.0 144.0
W 78.0 78.0 91.0 91.0 106.0 106.0
W1 25.0 25.0 30.0 30.0 35.0 35.0
W2 - 100.0 - 120.0 - 142.0
W3 - - 65.0 65.0 75.0 75.0
O'rnatish o'lchamlari A 25.0 25.0 30.0 30.0 35.0 35.0
B 117.0 117.0 128.0 128.0 125.0 125.0
od 3.5 3.5 4.5 4.5 5.5 5.5

CJMM1-400,630,800, Kontur va o'rnatish o'lchamlari (old panel ulanishi)

Olchamlari (mm) Model kodi
CJMM1-400S CJMM1-630S
Kontur o'lchamlari C 127 134
C1 173 184
E 89 89
F 65 65
G 26 29
G1 13.5 14
H 107 111
H1 150 162
H2 39 44
H3 6 6.5
H4 5 7.5
H5 4.5 4.5
L 257 271
L1 465 475
L2 225 234
W 150 183
W1 48 58
W2 198 240
A 44 58
O'rnatish o'lchamlari A1 48 58
B 194 200
Od 8 7

Orqa plataning ulanishini kesish diagrammasi

Olchamlari (mm) Model kodi
CJMM1-63S
CJMM1-63H
CJMM1-100S
CJMM1-100H
CJMM1-225S
CJMM1-225H
CJMM1-400S CJMM1-400H CJMM1-630S
CJMM1-630H
Orqa plataning ulanish vilkasi turining o'lchamlari A 25 30 35 44 44 58
od 3.5 4.5*6
chuqur teshik
3.3 7 7 7
od1 - - - 12.5 12.5 16.5
od2 6 8 8 8.5 9 8.5
oD 8 24 26 31 33 37
oD1 8 16 20 33 37 37
H6 44 68 66 60 65 65
H7 66 108 110 120 120 125
H8 28 51 51 61 60 60
H9 38 65.5 72 - 83.5 93
H10 44 78 91 99 106.5 112
H11 8.5 17.5 17.5 22 21 21
L2 117 136 144 225 225 234
L3 117 108 124 194 194 200
L4 97 95 9 165 163 165
L5 138 180 190 285 285 302
L6 80 95 110 145 155 185
M M6 M8 M10 - - -
K 50.2 60 70 60 60 100
J 60.7 62 54 129 129 123
M1 M5 M8 M8 M10 M10 M12
W1 25 35 35 44 44 58

MCCB nima?

Kalıplanmış korpusli avtomatik o'chirgichlar - bu elektr zanjirini haddan tashqari tokdan himoya qilish uchun mo'ljallangan elektr himoya vositalari. Bu ortiqcha tok ortiqcha yuklanish yoki qisqa tutashuv tufayli yuzaga kelishi mumkin. Kalıplanmış korpusli avtomatik o'chirgichlar keng kuchlanish va chastota diapazonida, sozlanishi mumkin bo'lgan o'chirish sozlamalarining belgilangan pastki va yuqori chegarasi bilan ishlatilishi mumkin. O'chirish mexanizmlaridan tashqari, MCCBlar favqulodda vaziyatlarda yoki texnik xizmat ko'rsatish operatsiyalarida qo'lda o'chirish kalitlari sifatida ham ishlatilishi mumkin. MCCBlar barcha muhitlar va ilovalarda xavfsiz ishlashni ta'minlash uchun ortiqcha tok, kuchlanishning ko'tarilishi va nosozliklardan himoya qilish uchun standartlashtirilgan va sinovdan o'tgan. Ular elektr zanjiri uchun quvvatni uzish va zanjirning ortiqcha yuklanishi, yerga urish, qisqa tutashuvlar yoki tok tok chegarasidan oshib ketganda keltirib chiqaradigan zararni minimallashtirish uchun qayta o'rnatish kaliti sifatida samarali ishlaydi.

 

Kalıplanmış korpusning ahamiyatiO'chirish to'xtatuvchisiElektr xavfsizligini ta'minlash bo'yicha

Bugungi zamonaviy dunyoda elektr energiyasi kundalik hayotimizning muhim qismidir. Uylarimizni elektr bilan ta'minlashdan tortib, sanoat mashinalarini boshqarishgacha, elektr tizimlarining xavfsizligi va ishonchliligini ta'minlash juda muhimdir. Qoliplangan korpusli avtomatik o'chirgich (MCCB) muhim rol o'ynaydigan asosiy komponent hisoblanadi. Ushbu blogda biz MCCBlarning elektr xavfsizligini ta'minlashdagi ahamiyatini o'rganamiz.

MCCB - bu elektr zanjirlari va uskunalarini ortiqcha yuklanish va qisqa tutashuvlardan himoya qilish uchun mo'ljallangan elektr himoya vositasi. Ular odatda turar-joy, tijorat va sanoat qo'llanmalarida elektr tizimlariga zarar yetkazilishining oldini olish va eng muhimi, elektr yong'inlari xavfini kamaytirish uchun ishlatiladi.

MCCB ning asosiy funktsiyalaridan biri ortiqcha yuklanish yoki qisqa tutashuv holatida tok oqimini to'xtatishdir. Bu simlar va komponentlarning qizib ketishining oldini olish uchun juda muhimdir, bu esa yong'inlar va halokatli zararlarga olib kelishi mumkin. MCCBlar zanjirlarni o'chirib qo'yish va elektr energiyasini uzish orqali potentsial xavflarning oldini olishga va odamlar va mulkni himoya qilishga yordam beradi.

Bundan tashqari, MCCB elektr tizimlariga ma'lum darajada qulaylik va moslashuvchanlikni ta'minlaydi. Ularni ishdan bo'shatilgandan so'ng osongina qayta o'rnatish mumkin, bu esa hech qanday komponentlarni almashtirishga hojat qoldirmasdan quvvatni tezda tiklash imkonini beradi. Bu nafaqat vaqt va kuchni tejaydi, balki uzilishlar va kundalik operatsiyalarning buzilishini minimallashtiradi.

Elektr xavflarining oldini olish funktsiyasidan tashqari, quyma korpusli avtomatik o'chirgichlar elektr tizimlarining umumiy samaradorligi va ishonchliligini oshirishga yordam beradi. Haddan tashqari yuklanish va qisqa tutashuvlardan himoya qilish orqali ular elektr uskunalarining yaxlitligini saqlashga va uning xizmat muddatini uzaytirishga yordam beradi. Bu o'z navbatida qimmat ta'mirlash va almashtirish zaruratini kamaytiradi, uzoq muddatda vaqt va pulni tejaydi.

Shuni ta'kidlash kerakki, barcha MCCBlar bir xil emas. Muayyan dastur uchun MCCB ni tanlashda tok kuchi, uzilish qobiliyati va ish kuchlanishi kabi omillarni hisobga olish juda muhimdir. Tegishli himoya va ishlashni ta'minlash uchun ushbu texnik xususiyatlar elektr tizimining talablariga diqqat bilan moslashtirilishi kerak.

Bundan tashqari, MCCB ning doimiy samaradorligini ta'minlash uchun uni muntazam ravishda texnik xizmat ko'rsatish va sinovdan o'tkazish juda muhimdir. Muntazam tekshiruvlar va sinovlar har qanday potentsial muammolarni yoki aşınma va yirtilishni aniqlashga yordam beradi, shuning uchun kerak bo'lganda ta'mirlash yoki almashtirish mumkin.

Xulosa qilib aytganda, quyma korpusli avtomatik o'chirgichlar elektr xavfsizligi va ishonchliligini ta'minlashda muhim rol o'ynaydi. Haddan tashqari yuklanish va qisqa tutashuvlardan himoya qilish orqali ular elektr xavflarining oldini olishga va yong'in xavfini minimallashtirishga yordam beradi. Bundan tashqari, ular elektr tizimlarining samaradorligi va uzoq umr ko'rishini oshirishga yordam beradi, bu ularni zamonaviy elektr inshootlarida ajralmas komponentga aylantiradi. Sifatli MCCBga investitsiya qilish va uning to'g'ri texnik xizmat ko'rsatilishini ta'minlash odamlar va mulkni elektr nosozliklari xavfidan himoya qilish uchun juda muhimdir.