CJ: Korxona kodi
M: Qoliplangan korpusli elektron to'xtatuvchi
1: Dizayn raqami
□: Kadrning nominal oqimi
□: Sindirish qobiliyati xarakteristikasi kodi/S standart turni bildiradi (S tushirib qolishi mumkin) H yuqori turni bildiradi
Eslatma: To'rt fazali mahsulot uchun to'rt xil neytral qutb (N qutb) mavjud. A turdagi neytral qutb ortiqcha tokni o'chirish elementi bilan jihozlanmagan, u har doim yoqilgan va boshqa uchta qutb bilan birga yoqilmagan yoki o'chirilmagan.
B turidagi neytral qutb ortiqcha tokni o'chirish elementi bilan jihozlanmagan va u boshqa uchta qutb bilan birga yoqilgan yoki o'chirilgan (neytral qutb o'chirilishidan oldin yoqilgan). C turidagi neytral qutb ortiqcha tokni o'chirish elementi bilan jihozlangan va u boshqa uchta qutb bilan birga yoqilgan yoki o'chirilgan (neytral qutb o'chirilishidan oldin yoqilgan). D turidagi neytral qutb ortiqcha tokni o'chirish elementi bilan jihozlangan, u har doim yoqilgan va boshqa uchta qutb bilan birga yoqilgan yoki o'chirilgan emas.
| Aksessuar nomi | Elektron nashr | Murakkab ajralib chiqish | ||||||
| Yordamchi kontakt, kuchlanish ostida uzilish, alam kontakt | 287 | 378 | ||||||
| Ikkita yordamchi aloqa to'plami, signal aloqasi | 268 | 368 | ||||||
| Shuntni bo'shatish, signalizatsiya kontakti, yordamchi kontakt | 238 | 348 | ||||||
| Kuchlanish ostida, signal bilan aloqa | 248 | 338 | ||||||
| Yordamchi kontaktli signalizatsiya kontakti | 228 | 328 | ||||||
| Shuntni bo'shatish signalizatsiya kontakti | 218 | 318 | ||||||
| Yordamchi kontaktning past kuchlanishli chiqarilishi | 270 | 370 | ||||||
| Ikki yordamchi kontakt to'plami | 260 | 360 | ||||||
| Shuntning past kuchlanishli chiqarilishi | 250 | 350 | ||||||
| Shuntni bo'shatish uchun yordamchi kontakt | 240 | 340 | ||||||
| Past kuchlanishli uzilish | 230 | 330 | ||||||
| Yordamchi aloqa | 220 | 320 | ||||||
| Shuntning chiqarilishi | 210 | 310 | ||||||
| Signal aloqasi | 208 | 308 | ||||||
| Aksessuar yo'q | 200 | 300 | ||||||
| 1 O'chirgichlarning nominal qiymati | ||||||||
| Model | Imax (A) | Texnik xususiyatlar (A) | Nominal ish kuchlanishi (V) | Nominal izolyatsiya kuchlanishi (V) | Reanimatsiya (kA) | ICS (kA) | Qutblar soni (P) | Yoy masofasi (mm) |
| CJMM1-63S | 63 | 6,10,16,20 25, 32, 40, 50,63 | 400 | 500 | 10* | 5* | 3 | ≤50 |
| CJMM1-63H | 63 | 400 | 500 | 15* | 10* | 3,4 | ||
| CJMM1-100S | 100 | 16,20,25,32 40,50,63, 80,100 | 690 | 800 | 35/10 | 22/5 | 3 | ≤50 |
| CJMM1-100H | 100 | 400 | 800 | 50 | 35 | 2,3,4 | ||
| CJMM1-225S | 225 | 100,125, 160,180, 200,225 | 690 | 800 | 35/10 | 25/5 | 3 | ≤50 |
| CJMM1-225H | 225 | 400 | 800 | 50 | 35 | 2,3,4 | ||
| CJMM1-400S | 400 | 225,250, 315,350, 400 | 690 | 800 | 50/15 | 35/8 | 3,4 | ≤100 |
| CJMM1-400H | 400 | 400 | 800 | 65 | 35 | 3 | ||
| CJMM1-630S | 630 | 400,500, 630 | 690 | 800 | 50/15 | 35/8 | 3,4 | ≤100 |
| CJMM1-630H | 630 | 400 | 800 | 65 | 45 | 3 | ||
| Eslatma: 400V, 6A uchun sinov parametrlari isitishsiz chiqarilganda | ||||||||
| 2 Quvvat taqsimoti uchun ortiqcha oqimning har bir qutbi bir vaqtning o'zida yoqilganda teskari vaqtni uzish operatsiyasining xarakteristikasi | ||||||||
| Sinov elementi Oqim (I/Kirish) | Sinov vaqt zonasi | Boshlang'ich holat | ||||||
| Qo'zg'almas tok 1.05 dyuym | 2 soat(n>63A), 1 soat(n<63A) | Sovuq holat | ||||||
| O'chirish oqimi 1.3In | 2 soat(n>63A), 1 soat(n<63A) | Darhol davom eting 1-sonli sinovdan keyin | ||||||
| 3 Har bir qutb haddan tashqari ko'p bo'lganda teskari vaqtni uzish operatsiyasining xarakteristikasi motorni himoya qilish uchun oqimning chiqarilishi bir vaqtning o'zida yoqilgan. | ||||||||
| Joriy an'anaviy vaqtni sozlash Boshlang'ich holat | Eslatma | |||||||
| 1.0 dyuym | >2 soat | Sovuq holat | ||||||
| 1.2 dyuym | ≤2 soat | 1-sonli sinovdan so'ng darhol davom etdi | ||||||
| 1.5 dyuym | ≤4 daqiqa | Sovuq holat | 10≤In≤225 | |||||
| ≤8 daqiqa | Sovuq holat | 225≤In≤630 | ||||||
| 7.2 dyuym | 4s≤T≤10s | Sovuq holat | 10≤In≤225 | |||||
| 6s≤T≤20s | Sovuq holat | 225≤In≤630 | ||||||
| 4 Quvvatni taqsimlash uchun avtomatik o'chirgichning bir zumda ishlash xususiyati 10 dyuym + 20% ga, motorni himoya qilish uchun avtomatik o'chirgichning xususiyati esa 12ln ± 20% ga o'rnatiladi. |
CJMM1-63, 100, 225, Kontur va o'rnatish o'lchamlari (old panel ulanishi)
| Olchamlari (mm) | Model kodi | |||||||
| CJMM1-63S | CJMM1-63H | CJMM1-63S | CJMM1-100S | CJMM1-100H | CJMM1-225S | CJMM1-225 | ||
| Kontur o'lchamlari | C | 85.0 | 85.0 | 88.0 | 88.0 | 102.0 | 102.0 | |
| E | 50.0 | 50.0 | 51.0 | 51.0 | 60.0 | 52.0 | ||
| F | 23.0 | 23.0 | 23.0 | 22.5 | 25.0 | 23.5 | ||
| G | 14.0 | 14.0 | 17.5 | 17.5 | 17.0 | 17.0 | ||
| G1 | 6.5 | 6.5 | 6.5 | 6.5 | 11.5 | 11.5 | ||
| H | 73.0 | 81.0 | 68.0 | 86.0 | 88.0 | 103.0 | ||
| H1 | 90.0 | 98.5 | 86.0 | 104.0 | 110.0 | 127.0 | ||
| H2 | 18.5 | 27.0 | 24.0 | 24.0 | 24.0 | 24.0 | ||
| H3 | 4.0 | 4.5 | 4.0 | 4.0 | 4.0 | 4.0 | ||
| H4 | 7.0 | 7.0 | 7.0 | 7.0 | 5.0 | 5.0 | ||
| L | 135.0 | 135.0 | 150.0 | 150.0 | 165.0 | 165.0 | ||
| L1 | 170.0 | 173.0 | 225.0 | 225.0 | 360.0 | 360.0 | ||
| L2 | 117.0 | 117.0 | 136.0 | 136.0 | 144.0 | 144.0 | ||
| W | 78.0 | 78.0 | 91.0 | 91.0 | 106.0 | 106.0 | ||
| W1 | 25.0 | 25.0 | 30.0 | 30.0 | 35.0 | 35.0 | ||
| W2 | - | 100.0 | - | 120.0 | - | 142.0 | ||
| W3 | - | - | 65.0 | 65.0 | 75.0 | 75.0 | ||
| O'rnatish o'lchamlari | A | 25.0 | 25.0 | 30.0 | 30.0 | 35.0 | 35.0 | |
| B | 117.0 | 117.0 | 128.0 | 128.0 | 125.0 | 125.0 | ||
| od | 3.5 | 3.5 | 4.5 | 4.5 | 5.5 | 5.5 | ||
CJMM1-400,630,800, Kontur va o'rnatish o'lchamlari (old panel ulanishi)
| Olchamlari (mm) | Model kodi | |||||||
| CJMM1-400S | CJMM1-630S | |||||||
| Kontur o'lchamlari | C | 127 | 134 | |||||
| C1 | 173 | 184 | ||||||
| E | 89 | 89 | ||||||
| F | 65 | 65 | ||||||
| G | 26 | 29 | ||||||
| G1 | 13.5 | 14 | ||||||
| H | 107 | 111 | ||||||
| H1 | 150 | 162 | ||||||
| H2 | 39 | 44 | ||||||
| H3 | 6 | 6.5 | ||||||
| H4 | 5 | 7.5 | ||||||
| H5 | 4.5 | 4.5 | ||||||
| L | 257 | 271 | ||||||
| L1 | 465 | 475 | ||||||
| L2 | 225 | 234 | ||||||
| W | 150 | 183 | ||||||
| W1 | 48 | 58 | ||||||
| W2 | 198 | 240 | ||||||
| A | 44 | 58 | ||||||
| O'rnatish o'lchamlari | A1 | 48 | 58 | |||||
| B | 194 | 200 | ||||||
| Od | 8 | 7 | ||||||
Orqa plataning ulanishini kesish diagrammasi
| Olchamlari (mm) | Model kodi | ||||||
| CJMM1-63S CJMM1-63H | CJMM1-100S CJMM1-100H | CJMM1-225S CJMM1-225H | CJMM1-400S | CJMM1-400H | CJMM1-630S CJMM1-630H | ||
| Orqa plataning ulanish vilkasi turining o'lchamlari | A | 25 | 30 | 35 | 44 | 44 | 58 |
| od | 3.5 | 4.5*6 chuqur teshik | 3.3 | 7 | 7 | 7 | |
| od1 | - | - | - | 12.5 | 12.5 | 16.5 | |
| od2 | 6 | 8 | 8 | 8.5 | 9 | 8.5 | |
| oD | 8 | 24 | 26 | 31 | 33 | 37 | |
| oD1 | 8 | 16 | 20 | 33 | 37 | 37 | |
| H6 | 44 | 68 | 66 | 60 | 65 | 65 | |
| H7 | 66 | 108 | 110 | 120 ta | 120 ta | 125 | |
| H8 | 28 | 51 | 51 | 61 | 60 | 60 | |
| H9 | 38 | 65.5 | 72 | - | 83.5 | 93 | |
| H10 | 44 | 78 | 91 | 99 | 106.5 | 112 | |
| H11 | 8.5 | 17.5 | 17.5 | 22 | 21 | 21 | |
| L2 | 117 | 136 | 144 | 225 | 225 | 234 | |
| L3 | 117 | 108 | 124 | 194 | 194 | 200 | |
| L4 | 97 | 95 | 9 | 165 | 163 | 165 | |
| L5 | 138 | 180 | 190 | 285 | 285 | 302 | |
| L6 | 80 | 95 | 110 | 145 | 155 | 185 | |
| M | M6 | M8 | M10 | - | - | - | |
| K | 50.2 | 60 | 70 | 60 | 60 | 100 | |
| J | 60.7 | 62 | 54 | 129 | 129 | 123 | |
| M1 | M5 | M8 | M8 | M10 | M10 | M12 | |
| W1 | 25 | 35 | 35 | 44 | 44 | 58 | |
Kalıplanmış korpusli avtomatik o'chirgichlar - bu elektr zanjirini haddan tashqari tokdan himoya qilish uchun mo'ljallangan elektr himoya vositalari. Bu ortiqcha tok ortiqcha yuklanish yoki qisqa tutashuv tufayli yuzaga kelishi mumkin. Kalıplanmış korpusli avtomatik o'chirgichlar keng kuchlanish va chastota diapazonida, sozlanishi mumkin bo'lgan o'chirish sozlamalarining belgilangan pastki va yuqori chegarasi bilan ishlatilishi mumkin. O'chirish mexanizmlaridan tashqari, MCCBlar favqulodda vaziyatlarda yoki texnik xizmat ko'rsatish operatsiyalarida qo'lda o'chirish kalitlari sifatida ham ishlatilishi mumkin. MCCBlar barcha muhitlar va ilovalarda xavfsiz ishlashni ta'minlash uchun ortiqcha tok, kuchlanishning ko'tarilishi va nosozliklardan himoya qilish uchun standartlashtirilgan va sinovdan o'tgan. Ular elektr zanjiri uchun quvvatni uzish va zanjirning ortiqcha yuklanishi, yerga urish, qisqa tutashuvlar yoki tok tok chegarasidan oshib ketganda keltirib chiqaradigan zararni minimallashtirish uchun qayta o'rnatish kaliti sifatida samarali ishlaydi.