| Turi | Texnik ko'rsatkichlar | ||||||
| Chiqish | DC kuchlanishi | 5V | 12V | 18V | 24V | 36V | 48V |
| Nominal oqim | 50A | 29A | 19.4A | 14.5A | 9.7A | 7.3A | |
| Nominal quvvat | 250 Vt | 350 Vt | 350 Vt | 350 Vt | 350 Vt | 350.4 Vt | |
| To'lqin va shovqin | <150mVp-p | <150mVp-p | <150mVp-p | <150mVp-p | <240mVp-p | <240mVp-p | |
| Voltajni boshqarish diapazoni | ±10% | ||||||
| Voltaj aniqligi | ±2.0% | ±1.0% | |||||
| Chiziqli sozlash tezligi | ±1% | ||||||
| Yukni qayta tartibga solish tezligi | <±1.5% | <±1.2% | <±1.2% | <±1% | <±0,5% | <±0,5% | |
| Kirish | Kuchlanish diapazoni/chastotasi | 90-132VAC/180-264VAC 47Hz-63Hz (254VDC ~ 370VDC) | |||||
| Samaradorlik (odatiy) | >74% | >82% | >82% | >84% | >86% | >86% | |
| Ishchi tok/Shok tok | <5.2A 115VAC; <2.8A 230VAC | ||||||
| Shok oqimi | 110VAC 25A, 220AC:50A | ||||||
| Boshlash vaqti | 200ms, 50ms, 20ms; 220VAC | ||||||
| Himoya xususiyatlari | Haddan tashqari yukdan himoya | ≥105%-150%; Doimiy tok chiqishi +VO bosim ostidagi nuqtaga tushadi, uzilgan chiqish qayta o'rnatiladi: qayta yoqing | |||||
| Haddan tashqari kuchlanishdan himoya | ≥115%-145% Chiqishni yoping | ||||||
| Past kuchlanishli himoya | ≤10%-45% Chiqishni yoping | ||||||
| Qisqa tutashuvdan himoya | Chiqishni yoping | ||||||
| Haddan tashqari qizib ketishdan himoya | Chiqishni o'chiring (himoya rejimi: chiqishni o'chiring va harorat normal holatga qaytganda avtomatik ravishda ishga tushiring) | ||||||
| Atrof-muhit fanlari | Ish harorati va namlik | -10ºC~+50ºC;20%~90RH | |||||
| Saqlash harorati va namligi | -20ºC ~ +85ºC; 10% ~ 95NH | ||||||
| Xavfsizlik | Bosim qarshiligi | Kirish – chiqish: 1.5KVAC kirish korpusi: 1.5KVAC chiqish korpusi: 0.5kVAC davomiyligi: 1 daqiqa | |||||
| oqish oqimi | Kirish-chiqish 1.5KVAC <5mA | ||||||
| oqish oqimi | Kirish-chiqish 220VAC <1mA | ||||||
| Izolyatsiya empedansi | Kirish-chiqish va kirish-qobiq, chiqish-qobiq: 500 VDC/100mΩ | ||||||
| Boshqa | Hajmi | 215*114*50 mm (U*K*B) | |||||
| Sof og'irlik / brutto og'irlik | 874.1 g/936.3 g | ||||||
| Izohlar | (1) To'lqin va shovqinni o'lchash: Terminalda parallel ravishda 0,1uF va 47uF kondensatorli 12 dyuymli o'ralgan juftlik liniyasidan foydalanib, o'lchash 20 MGts chastotali o'tkazish qobiliyatida amalga oshiriladi. | ||||||
| (2) Samaradorlik 230VAC kirish kuchlanishida, nominal yukda va 25ºC atrof-muhit haroratida sinovdan o'tkaziladi. Aniqlik: sozlash xatosi, chiziqli sozlash tezligi va yukni sozlash tezligini o'z ichiga oladi. Chiziqli sozlash tezligini sinov usuli: nominal yukda past kuchlanishdan yuqori kuchlanishgacha sinovdan o'tkazish. Yukni sozlash tezligini sinov usuli: 0%-100% nominal yukdan. Ishga tushirish vaqti sovuq ishga tushirish holatida o'lchanadi va tez-tez almashtirish mashinasi ishga tushirish vaqtini oshirishi mumkin. Balandlik 2000 metrdan yuqori bo'lganda, ish harorati 5/1000 ga tushirilishi kerak. | |||||||